Qty 1-9 | 10-49 | 50-99 | 100-199 | 200-319 | 320-999 | 1000+ |
$249 | Register for Volume Pricing | CONTACT |
ClearLink CLNK-4-13 | Add to cart | ||||
Terminal Block Plugs CC-3TERM-PLUG-10PC |
Each ClearLink Industrial I/O and Motion Controller handles up to 4 axes of high-speed step & direction motion, and provides 13 software-configurable analog and digital I/O points (fully protected and 24 VDC compatible); compatible with any EtherNet/IP PLC.
Rich EDS file support reduces development time. LEDs for each I/O point provide easier troubleshooting to reduce downtime.
You can expand each ClearLink’s digital I/O by adding up to eight CCIO-8 expansion modules. This provides up to an additional 64 points of configurable digital I/O.
See the ClearLink main product page for more information.
Drawings | |
ClearLink-and-Accessories.pdf | 2D Drawings |
clearlink-accessories-3d.zip | 3D Drawings / Solid Models |
Manuals | |
clearlink_user_manual.pdf | ClearLink User Manual |
ClearLink EtherNet/IP Object Reference | Object data reference guide |
ClearLink EDS/Examples | Electronic datasheet and examples for EtherNet/IP |
Mechanical | |
Dimensions | 5.0" x 3.5" x 1.0" (127mm x 88.9mm x 25.4mm) |
Weight (with cover) | 0.40 lbs (181 g) |
Material | 3mm thick Polycarbonate cover, aluminum mount frame |
Electrical | |
Voltage Input | 20-28 VDC |
Output Current Capability | I/O 0,1,2,3 - 375 mA RMS, (750mA peak) I/O 4,5 - 500 mA RMS, (1,000mA peak) |
Indicator LEDs for each input | Yes |
IP Rating | IP20 |
Regulatory Certifications | CE, RoHS |
Safety | Low Voltage Directive 2014/35/EU, EN 61010-1:2010 |
Operating Temperature/Humidity | -20C to 50C, 0-90% non-condensing |
Storage Temperature | -40C to 85C |
Power Consumption | 300mA@24V |
Protection features | Overcurrent protection on all outputs Inductive clamping on all outputs Board master overvoltage and overcurrent protection ESD protection features on all I/O circuits |
Processing/Communication | |
Total I/O | 13 built-in I/O points, software configurable as any combination of up to 13 digital inputs, 4 analog inputs, 6 digital outputs, and 1 analog output (4-20mA or 0-20mA). Another 64 digital I/O can be added by using optional 8-point I/O expansion modules (p/n CCIO-8). All configuration of I/O hardware is controlled by software, i.e., no jumpers, DIP switches, trim-pots, etc. need to be manually set. |
Serial communication | 1 multi-functional, individually configurable serial port that can be used as a UART, or RS-232 at up to 115.2 kBaud. Rates up to 2MBaud are achievable depending on cable length, slave transceiver circuit and grounding. 5V power pins are available on each port. |
Ethernet | 10Base-T/100Base-TX Ethernet EtherNet/IP Explicit & Implicit Messaging Adapter |
Max Step Rate | 500kHz (step pulse width fixed at 1 microsecond) |
Terminal Block Plugs, 3-position (pack of 10)
Part Number: CC-3TERM-PLUG-10PC
Qty 1-9 | Qty 10-49 | Qty 50-99 | Qty 100-199 | Qty 200+ |
---|---|---|---|---|
$9 | REQUIRES QUICK REGISTRATION | CONTACT |
24 VDC Power Supply
Part Number: PWR-IO-24VDC
Output Voltage: 24 VDC
Output Current: 6.5 Amps
Input Voltage: 85-264 VAC, auto-selected
Dimensions: 159x97x30mm (6.26x3.82x1.18 in.)
Qty 1-9 | Qty 10-49 | Qty 50-99 | Qty 100-199 | Qty 200+ |
---|---|---|---|---|
$39 | REQUIRES QUICK REGISTRATION | CONTACT |
Digital I/O Expansion, 8-point
Part Number: CCIO-8
Regulatory Certifications: CE, RoHS
Safety: Low Voltage Directive 2014/35/EU, EN 61010-1:2010
Qty 1-9 | Qty 10-49 | Qty 50-99 | Qty 100-199 | Qty 200+ |
---|---|---|---|---|
$49 | REQUIRES QUICK REGISTRATION | CONTACT |
Cat5e Patch Cable
Part Number: CABLE-CAT5-120
Connectors: RJ45
Length: 3.05 meters (10 ft)
Qty 1-9 | Qty 10-49 | Qty 50-99 | Qty 100-199 | Qty 200+ |
---|---|---|---|---|
$9 | REQUIRES QUICK REGISTRATION | CONTACT |
DIN Rail Mounting Kit
Part Number: DIN-MNT
Dimensions: 123x91mm (4.86x3.60 in.)
Qty 1-9 | Qty 10-49 | Qty 50-99 | Qty 100-199 | Qty 200+ |
---|---|---|---|---|
$19 | REQUIRES QUICK REGISTRATION | CONTACT |
Encoder Input Adapter
Part Number: CL-ENCDR-DFIN
Dimensions: 64x44x20 mm (2.52x1.73x0.79 in.)
Max Count Rate: 2 MHz (quadrature counts/sec)
Index Capture Accuracy: +/- 1 count
Regulatory Certifications: CE, RoHS
Safety: Low Voltage Directive 2014/35/EU, EN 61010-1:2010
Qty 1-9 | Qty 10-49 | Qty 50-99 | Qty 100-199 | Qty 200+ |
---|---|---|---|---|
$39 | REQUIRES QUICK REGISTRATION | CONTACT |
Quantities up to 5 generally ship within 3 business days.
Easily connect 6 signals from a differential quadrature encoder (A+ A~, B+ B~ and optionally I+ I~) to ClearLink using only 3 digital inputs (DI-6, 7 and 8), without wiring to separate terminal blocks. Connect your encoder to the adapter's DB-9 input and connect the adapter to ClearLink with a standard ribbon cable (20-pin, 0.1" pitch) for a simple noise-free setup. The adapter provides overload-protected +5 volts for the encoder, and "bad sequence" detection warns of faulty or dirty encoders.
CL-ENCDR-DFIN Encoder Input Adapter | CABLE-RIBBON6 6 inch ribbon cable |
See pricing above | $4 |
Add to cart | |
The "Add to Cart" button will add one of each component (adapter and cable) unless you edit the quantities. Type "0" for the quantity of any component you don't want to add to your cart. |